Presently, CLI utilities such as systemctl will check whether they have a tty
attached or not to decide whether to parse /proc/cmdline or EFI variable
SystemdOptions looking for systemd.log_* entries.
But this check will be misleading if these tools are being launched by a
daemon, such as a monitoring daemon or automation service that runs in
background.
Make log handling of CLI tools uniform by never checking /proc/cmdline or EFI
variables to determine the logging level.
Furthermore, introduce a new log_setup_cli() shortcut to set up common options
used by most command-line utilities.
chase_symlinks() would return negative on error, and either a non-negative status
or a non-negative fd when CHASE_OPEN was given. This made the interface quite
complicated, because dependning on the flags used, we would get two different
"types" of return object. Coverity was always confused by this, and flagged
every use of chase_symlinks() without CHASE_OPEN as a resource leak (because it
would this that an fd is returned). This patch uses a saparate output parameter,
so there is no confusion.
(I think it is OK to have functions which return either an error or an fd. It's
only returning *either* an fd or a non-fd that is confusing.)